S01-R004LED Downlights
Compare recessed downlights for general interior lighting. Product dimensions, ceiling cutouts, CCT and CRI are shown from the current catalog, with each power and size combination kept intact.
- series
- 13
- source configurations
- 72
Product range
13 series
Choose by the actual configuration
Each row is one catalog configuration. Options shown on different rows are not automatically interchangeable.
| Series / model | Power | Dimensions | Cutout | CCT | CRI |
|---|---|---|---|---|---|
| Recessed Downlight S01-R004 | 7 W | Φ85*H64 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 10 W | Φ85*H64 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 12 W | Φ85*H64 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 7 W | Φ90*H64 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 10 W | Φ90*H64 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 12 W | Φ90*H64 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 15 W | Φ105*H72 | φ95 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R004 | 20 W | Φ105*H72 | φ95 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R013 | 5 W | Φ90*H56 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R013 | 7 W | Φ90*H56 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R013 | 10 W | Φ90*H56 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R013 | 12 W | Φ90*H56 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R013 | 15 W | Φ105*H64 | φ95 | 3000 K/ | ≥85 |
| Shiguang Recessed Downlight S01-R019 | 7 W | Φ83*H50 | φ75 | 3000 K/ | ≥85 |
| Shiguang Recessed Downlight S01-R019 | 10 W | Φ83*H50 | φ75 | 3000 K/ | ≥85 |
| Shiguang Recessed Downlight S01-R019 | 12 W | Φ103*H63 | φ95 | 3000 K/ | ≥85 |
| Shiguang Recessed Downlight S01-R019 | 15 W | Φ123*H74 | φ115 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R024 | 7 W | Φ85*H55 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R024 | 10 W | Φ85*H55 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R024 | 7 W | Φ90*H55 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R024 | 10 W | Φ90*H55 | φ75-80 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R024 | 12 W | Φ108*H58 | φ95 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R024 | 15 W | Φ105*H64 | φ95 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 5 W | Φ100*H43 | φ75-90 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 7 W | Φ100*H43 | φ75-90 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 10 W | Φ120*H43 | φ90-110 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 12 W | Φ120*H43 | φ90-110 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 15 W | Φ150*H45 | φ120-140 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 18 W | Φ175*H50 | φ140-165 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 24 W | Φ197*H50 | φ160-185 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 30 W | Φ230*H50 | φ190-220 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R031 | 36 W | Φ230*H50 | φ190-220 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 5 W | Φ88*H46 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 7 W | Φ88*H46 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 9 W | Φ105*H60 | φ90 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 12 W | Φ105*H60 | φ90 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 12 W | Φ130*H68 | φ110 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 15 W | Φ130*H68 | φ110 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 20 W | Φ185*H93 | φ165 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 24 W | Φ185*H93 | φ165 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 25 W | Φ220*H98 | φ195 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R041 | 30 W | Φ220*H98 | φ195 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R052 | 7 W | Φ82*H43 | φ75 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R052 | 12 W | Φ103*H50 | φ95 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R052 | 18 W | Φ133*H55 | φ125 | 3000 K/ | ≥85 |
| Recessed Downlight S01-R056 | 7 W | Φ82*H58 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R056 | 10 W | Φ82*H58 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R056 | 12 W | Φ82*H58 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 5 W | Φ94*H64 | Φ80 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 7 W | Φ94*H64 | Φ80 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 10 W | Φ94*H64 | Φ80 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 12 W | Φ94*H64 | Φ80 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 12 W | Φ114*H68 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 15 W | Φ114*H68 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R060 | 20 W | Φ140*H74 | Φ120 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R068 | 7 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R068 | 10 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R068 | 12 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R068 | 12 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R068 | 15 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R068 | 18 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R075 | 7 W | Φ85*H70 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R075 | 10 W | Φ85*H70 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R075 | 12 W | Φ85*H70 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R079 | 7 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R079 | 10 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R079 | 12 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R079 | 15 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R084 | 7 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R084 | 10 W | Φ85*H55 | Φ75 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R084 | 12 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
| Recessed Downlight S01-R084 | 15 W | Φ105*H60 | Φ95 | 3000 K/ | ≥98 |
Selection guide
Match the ceiling opening and available installation depth first, then compare the listed optical and electrical configurations. A larger wattage does not automatically mean the same body or cutout.
A downlight schedule should start with the ceiling construction and the intended general-lighting task. Compare the actual housing diameter, depth and cutout before comparing power. The same wattage can appear in more than one size, so the table keeps every source configuration separate. Next review the recorded beam, colour temperature, colour rendering and electrical information. Do not infer an output value from power or efficacy alone when the source does not state the complete luminaire output. Product cards help narrow the range, while each series page preserves the full parameter set and separates genuinely common values from configuration-specific dimensions.
Installation & application planning
The front diameter and cutout are separate measurements. Confirm housing clearance, driver placement and the exact stated input voltage before installation.
For a hotel circulation area, reception or commercial interior, coordinate the fitting position with the ceiling grid and services before cutting openings. Check the stated installation method and space needed for the housing and driver. The product photograph documents the supplied design but does not establish fire resistance, suitability for insulation covering or use in a wet location. Only carry an IP rating into the project specification when it is explicitly recorded for that configuration. Keep access for the selected electrical equipment in the installation plan, and ask for the relevant product documentation where a project requires a tested construction detail.
- Hotel circulation
- Reception areas
- General interior lighting
Technical questions
Is the front diameter the ceiling cutout?
No. Use the separate cutout value and check housing depth. Do not size the ceiling opening from the product photograph or front diameter alone.
Does one wattage identify one body size?
Not necessarily. S01-R004 includes repeated power values with different body and cutout dimensions. Select the complete configuration rather than grouping by power alone.
Can power alone determine the spacing between downlights?
No. The listed wattage identifies electrical power, not a complete room-lighting result. Spacing also depends on the selected distribution, mounting height, room surfaces and the lighting task. Use the exact configuration as the starting point and request suitable photometric information for a calculation. Do not convert a catalog photograph or a power ladder into an unsupported spacing recommendation for a reception, corridor or other commercial interior.
Does a recessed downlight automatically suit wet areas?
The recessed format does not establish moisture protection. Read the IP information recorded for the precise configuration and confirm the installation conditions required by the project. An absent rating should not be replaced with a category-wide assumption, and a similar appearance is not evidence of equivalent protection. Keep any required approval or supporting document tied to the selected product rather than copying it from another downlight family.
What should I check when replacing an existing ceiling fitting?
Record the actual opening, available depth and the existing supply arrangement, then compare them with the chosen source configuration. Matching power or front diameter is not enough to establish a direct replacement. Review the stated input voltage and driver information as well as the mechanical dimensions. Keep the original fitting measurements separate from the new product specification, so a quotation can identify any installation differences before the replacement is ordered.
How do I specify a consistent downlight schedule?
Identify each series and configuration with its own power, body dimensions and cutout, then add the required catalog light-colour option and quantities. Retain shared values only when they genuinely apply to every selected configuration. CCT describes the appearance of the light and is different from the listed colour-rendering measure. Include room references and any required documentation in the inquiry so products for different ceiling conditions are not accidentally grouped under one wattage.
Plan your lighting specification
Send the selected series, configuration, quantities and project requirements. Keep dimensions, voltage and optical options tied to the exact configuration.